Safety control units

Safety control units
Wide Automation

Safety control units

  • Safety Control Units are electronic devices designed to monitor and control safety-related functions in machinery and equipment.
  • These units ensure that safety requirements are met, by monitoring various safety signals and taking appropriate actions in case of hazardous conditions.
  • Safety Control Units can be used in a wide range of applications, such as manufacturing, packaging, transportation, and robotics.
  • They can provide various safety features, including emergency stop, safety door interlock, light curtain, and two-hand control.
  • Safety Control Units from Wide Automation are designed to be easy to install and use, and can be customized to meet specific customer requirements.
  • They are compliant with international safety standards, such as ISO 13849 and IEC 61508, and have been certified by various independent testing organizations.
  • Wide Automation offers a range of Safety Control Units to meet different customer needs, including modular and compact models, with various input and output options.

Rating

Brand

Wide Automation

Wide Automation's Safety Control Units are designed to provide safety and control for automated systems. These units ensure that the equipment operates safely and efficiently, while minimizing the risk of accidents and injuries. The safety control units can be integrated with a range of safety devices, such as emergency stop buttons, light curtains, and safety interlock switches. They provide advanced functionality, including monitoring and diagnostics, and can be customized to meet the specific needs of the application. The safety control units are suitable for a variety of industries, including manufacturing, packaging, material handling, and robotics.

Specification Description
Model Safety Control Units
Manufacturer WIDE Automation
Series DYNATEX
Operating voltage 24 VDC (±20%)
Number of safety outputs 4 safety PNP outputs (OSSD)
Switching capacity per safety output 0.5 A (max)
Total switching capacity 2 A
Number of EDM inputs 2 (safety inputs)
Input type 2-channel input for safety sensors
Monitoring of safety outputs Automatic restart selectable
Configuration Configurable via PC with USB cable
LED indication Power, status, and diagnostic LEDs
Enclosure IP20, screw terminals
Operating temperature -25 to +55°C
Approvals CE, TÜV Rheinland
Get Latest Price